Customized Products
400℉/204℃ EPDM/LEAD Flat Electrical Submersible Pump Cable
Applications:
These cables are designed for transmitting power to the submersible motor in the oil industry, suitable for installed down well in the oil industry.
Standard:
IEEE Std. 1018 API RP 11S5 API RP 11S6
Construction:
Conductor: Solid copper conductor.
Insulation: EPDM insulation.
Jacket: Lead jacket. Each insulated conductor should have a lead sheath extruded over the insulation.
Bedding Layer: Bedding tape.
Armor: Galvanized steel.
Dimensions and Weight:
5KV
Cable Type | Conductor Size |
Conductor O.D. |
Insulation Thickness |
Overall O.D. | Approx. Weight |
|||
---|---|---|---|---|---|---|---|---|
AWG | mm² | mm | Inches | mm | Inches | mm | kg/km | |
QYEQ-204-5KV-3G2 |
2 |
33.62 |
6.54±0.07 |
0.07 |
1.9 |
0.63 x 1.67 |
16.0 x 42.5 |
3100 |
Electrical Data:
Voltage | KV AC |
5 |
---|---|---|
Minimum Insulation Resistance (15.6℃) | MΩ·km |
1294 |
Maximum DC Current Unbalance | % |
2 |
Maximum DC Leakage (15.6℃) | μA/(KV·km) |
0.77 |
Maximum DC Conductor Resistant | Ω/km |
0.522 |
DC 35KV/5min |
|
No breakdown |
Mechanical Data:
Temperature Rated | ℃ |
204 |
---|---|---|
Minimum Bending Radius | mm |
320 |